Panel selection is usually presented as a choice between products. In practice it is a sequence of decisions constrained by the site: the height follows the geometry, the construction follows the height and the structural base, the mass follows the acoustic case, and the finish follows the environment. Choosing a panel before working through that order is how projects end up with a specification that cannot be built or does not perform.
This page is the entry point for the structural and material side of the range. The detail pages cover heights from 2 m to 6 m, panel construction types, materials, finishes and the numbers a datasheet has to state.
| Step | Decision | Driven by |
|---|---|---|
| 1 | Barrier height | Source and receiver geometry, and where the criterion is measured |
| 2 | Structural base | Ground, wall, deck or parapet — and what it can carry |
| 3 | Panel construction | Height, base capacity, and whether absorption is needed |
| 4 | Mass per square metre | The acoustic case, especially the low-frequency bands |
| 5 | Absorption | Whether reflections would reach another receiver |
| 6 | Material and finish | Exposure: coastal, industrial, de-icing salt, visible location |
Most specification errors come from working down this list in the opposite direction — picking a panel with a good headline rating, then discovering that the height required is not structurally possible.
| Height | Typical use | Structural note |
|---|---|---|
| 2 m | Low screens, plant compounds, garden boundaries | Light posts; often freestanding |
| 3 m | Residential boundaries, low embankments | The common domestic and municipal height |
| 4 m | Roadside barriers at grade | Post spacing starts to govern cost |
| 5 m | Embankments and cuttings with tall receivers | Foundation becomes a significant item |
| 6 m | Tall barriers where geometry demands it | Wind load and foundation usually dominate cost |
Beyond about 4 m, the cost per square metre rises faster than the height because the structural share grows. That is the point at which comparing an alternative measure becomes worthwhile rather than a distraction.
Single skin — one metal sheet. Light and inexpensive, and weakest at low frequency. Suitable for low screens and short runs.
Double skin cassette — two sheets with infill between. The mainstream product: mass where needed, plus a cavity that can be filled.
Absorptive cassette — perforated or louvred face with absorber behind a protective membrane. Higher absorption, and the right choice on a source face where reflections matter.
Transparent infill — acrylic or polycarbonate in a frame, used where daylight or sightlines must be kept. Heavier than it appears and needing its own fixing detail.
Louvred absorptive — blades shielding the absorber from direct rain and dust, used on contaminated or exposed sites.
Three figures do most of the work, and they are not interchangeable:
Mass per unit area governs low-frequency performance. Doubling it buys roughly 5–6 dB, and the benefit is largest where traffic and machinery noise actually sit.
Sound reduction index (Rw or Dw) describes how much is stopped, but as a single figure weighted toward speech frequencies. Ask for octave bands where low frequency matters.
Absorption (NRC or the weighted coefficient) describes how much is not reflected back. A barrier beside a road usually wants both: absorptive on the traffic face, and enough mass to block transmission.
A datasheet that gives only one of these cannot be used to predict field performance. That is the central point of the specification page linked below.
| Substrate | Suits | Watch |
|---|---|---|
| Galvanised steel | General exterior use | Cut edges and hole rims corrode first |
| Powder-coated galvanised | Visible and architectural locations | Coating thickness matters more than colour |
| Aluminium | Coastal and lightweight applications | Lower strength; different fixing detail |
| Stainless | Aggressive industrial and marine | Specify the grade, not just the material |
| PMMA or polycarbonate | Transparent sections | Embrittlement, cleaning, and frame design |
On a bridge deck, allowable load usually limits mass, so the acoustic case may need a different measure rather than a heavier panel.
On a retaining wall, the coping decides how much moment can be transferred, which in turn decides post spacing and panel area.
On a cutting crest, terrain accelerates wind, so the same panel may need a heavier post than at grade.
On a viaduct parapet, panel weight is limited by what can be handled from the deck.
By height
2 m high noise barrier · 3 m high noise barrier · 4 m noise barrier panel · 5 m high noise barrier · 6 m high noise barrier
By performance figure
NRC 0.85 absorptive panels — high-absorption faces for source-side use.
STC 29 panels — the transmission rating, and what it does and does not tell you.
Panel specifications — the six numbers a datasheet must state.
Wind load and post spacing — the structural case that sizes everything above.
By material
Aluminium alloy noise barrier panels — coastal and lightweight applications.
Perforated metal noise barrier — open area, absorption and the dust problem.
Metal noise barrier manufacture — what separates two panels that look the same.
Solar noise barrier cost — photovoltaic integration and what it adds.
PMMA transparent noise barrier and fully enclosed noise barrier — the two structural forms that most often drive panel choice.
Cost
Noise barrier cost per square metre — what moves the price, and by how much.
Highway noise barrier cost — the road scheme case, where foundations dominate.
Road engineering noise barriers — section types and their structural consequences.
Rail and transit noise barriers — lines, stations and depots, and the constraints specific to rail.
Required reduction at the receiver, and the frequency band that matters if known.
Barrier height and total run length.
The structural base: ground, wall, deck or parapet, and its allowable load.
Whether the source face must absorb or reflect.
Exposure: coastal, industrial, de-icing salt, and any transparency requirement.
Fire performance class required by the project.
Items one and three together eliminate most of the range before a price is quoted.
Related reading: road engineering noise barriers, rail and transit noise barriers, and noise barrier panel range.
It follows from the geometry between source and receiver and from where the criterion is measured, not from a standard range. As a working reference, 2–3 m suits residential boundaries and low screens, 4 m suits roadside barriers at grade, and 5–6 m is used where receivers are elevated or the alignment sits below them.
For low-frequency noise, generally yes — mass is the governing property there and doubling it buys roughly 5–6 dB. But weight is limited by the structure, and on a bridge or a wall the allowable load may rule out the mass the acoustic case would otherwise ask for.
Where sound would otherwise reflect off the barrier toward another receiver, or where it faces the source in an enclosed space. A barrier beside a road usually benefits from absorption on the traffic face; a barrier protecting a single property from a distant source may not need it.
Rw describes how much sound the panel stops passing through; NRC describes how much it absorbs instead of reflecting. They describe opposite faces of the same performance and one does not substitute for the other.
A thicker coating on a suitable substrate, with attention to cut edges and fixings, which corrode first. Aluminium or stainless may be justified in aggressive marine exposure, but the coating specification and the fastener detail usually matter more than the base material alone.
Contact Us
Imfornation
1Wind Farm Noise: What a Barrier Can and Cannot Do4 Meter Noise Barrier PanelExpressway Widening: Upgrading an Existing Noise BarrierBiomass and CHP Noise: Fans, Vents and Continuous DutyStadium Noise Barrier: Crowd, PA and Plant Compounds3m High Noise BarrierNoise Barrier Height: How the Height Is Actually SetHighway Interchange Noise Barrier: Multi Level LayoutWarehouse Noise Barrier: Docks, Plant and YardsBridge Deck Noise Barrier: Load, Movement and AccessNoise Barrier Structure and Panel Selection: 2 m to 6 mGabion Baskets for saleNoise Barrier Maintenance: Inspection and RepairHotel Noise: Kitchen Extract, Chillers and DeliveriesAnti-Climb Fence Specification: 358 Mesh, Paladin Pales and 3D Panels111Construction Hoarding Panels: Wind Load and Site BoundariesGenerator Noise Barrier: Tonal Noise and AirflowMining and Quarry Noise Barriers: Dust, Plant and LayoutShopping Centre Noise: Rooftop Plant and DeliveriesAirport Noise Barrier: Ground Noise, Run-Up and PlantTunnel Portal Noise: Hoods, Barriers and AbsorptionRetaining Wall Noise Barrier: Wall Top Mounting and Load PathIndustrial Plant Noise Barrier: Boundary Wall and Equipment EnclosureNoise Control SolutionsLight Rail Noise Barrier: Street Running and CurvesGabion Mattress: Channel Lining and Scour Protection3D-Welded Mesh fencing systemFence Cost Per Metre: What Actually Moves the Price of a Boundary FenceGabion Basket SupplierConstruction Site Noise Barriers: Temporary Screens That Move With the WorksNoise Barrier Wind Load: Posts, Spacing and FoundationsPoultry Farm Noise: Ventilation Fans and GeneratorsInfrastructure Noise ControlRailway and HSR Noise Barriers: Design for Speed and ClearanceRailway Station Noise: Platforms, Plant and ApproachesRoad Engineering Noise Barrier: Sections and StructuresUrban Noise ControlSubstation and Transformer Noise Barriers: Controlling Low-Frequency HumAluminum Alloy Noise Barrier SupplierData Centre Cooling Noise: Louvre Screens and AirflowChain Link Fence: Wire, Mesh and Coating SelectionMetro Viaduct Noise Barrier: Deck Radiated NoiseCutting and Embankment Noise Barrier: Section Geometry