In short: a barrier is a screen, and a screen is bypassed at its edges. Sound reaches the receiver around the ends and through every gap, and those flanking paths are the usual reason a measured insertion loss falls short of the calculated one. A short return at the end is often worth more than a metre of extra height.
This is also the cheapest improvement available on an existing barrier that is underperforming, because it adds a small area rather than a new structure.
Because the calculation assumes an infinite screen. In reality the sound path around the end is short, so it competes with the path over the top, and at receptors positioned beyond the barrier line it can dominate.
The diffraction path around a vertical edge is comparable to the path over the top edge for many geometries.
Receptors obliquely opposite the end receive very little benefit from the barrier at all.
The effect is greatest when the barrier is short relative to the distance to the receiver.
It is also why a barrier protecting one building is easier to get right than one protecting a terrace.
A section of barrier turned perpendicular at the end, so that the flanking path has to travel further and is intercepted by the return itself.
The return interrupts the direct line from the source to the receptor around the end.
It is most effective when turned toward the source side, not away from it.
It does not need to be as tall as the main run to be useful, because the path it blocks is at a shallow angle.
It can follow terrain or an existing wall instead of being a free-standing structure.
Long enough that the line of sight from the furthest protected receiver to the source is interrupted. As a starting point that is often several times the barrier height, and it should be confirmed by modelling the actual geometry rather than by rule of thumb.
Model the return length against the furthest exposed receptor, not the nearest.
Check the return at the receptor that stands obliquely beyond the end, which gains least.
Where terrain or a building already blocks the flank, a return may be unnecessary.
A return that is too short can give a false sense of protection while barely changing the level.
| Flanking path | Where it occurs | How to close it |
|---|---|---|
| Around the end | Beyond the barrier line, obliquely opposite | Perpendicular end return toward the source |
| Through a door | Access points and maintenance routes | Lobby or double-door, self-closing |
| Through a penetration | Gantry legs, lighting, ducts, cables | Acoustic collar or flexible sealed boot |
| Over a dropped panel | Panels removed for access and not replaced | Inspection and asset record |
| Under the base | Gap between panel and ground | Continuous base seal, no litter void |
Each gap is a local short circuit. A door left open, a missing panel for access, or an unsealed penetration behaves like a hole in the screen, and the loss is concentrated around it rather than spread evenly.
Use a lobby or double-door arrangement rather than a single door with better seals.
Specify acoustic collars and flexible boots around ducts and cables.
Check that gantry legs and lighting columns are sealed at the penetration, not just structurally fixed.
Inspect for panels removed for maintenance and not replaced, which is a common finding.
Favourably, if they are used deliberately. A barrier that terminates against a building, a retaining wall or a rise in the ground closes its own flank and needs a much shorter return, or none.
Terminating into a structure is usually better than ending in open ground.
Where the ground rises behind the barrier, the effective height increases and the flank shortens.
Where the ground falls away, the barrier loses height and the flank lengthens, which is the worst combination.
Check the as-built ground levels, because the design is often drawn on a different surface.
It is not a uniform loss; it is a local one, concentrated in the sector that can see through the gap. That is why a barrier can meet its specification on average and still fail at the one dwelling that complains.
In-situ measurement should be made at the dwelling, not at a convenient point along the barrier.
Check several receiver positions, including the one beyond the end.
A tonal or impulsive source makes any leak more audible, because the spectrum that escapes is not the average spectrum.
Compare measured and calculated results before adding height; the difference usually points to the flank.
Continue the post and panel system around the corner, rather than improvising a closure.
Keep the return structurally independent enough to accommodate movement.
Maintain the acoustic seal at the corner joint, which is a common weak point.
Provide access so that the return can be inspected and repaired.
Detail drainage so that water does not pond behind the return.
Require the end treatment to be shown on the drawing, not left to the contractor.
Require the flanking path to be considered in the acoustic model.
Require in-situ verification at the nearest receptor, to ISO 10847.
Require the as-built condition to be recorded, including any gaps left for access.
ISO 9613-2 — outdoor sound propagation, including barrier and flanking geometry.
ISO 10847 — in-situ insertion loss determination.
EN 14388 — product specification for noise reducing devices.
EN 1793-2 — airborne sound insulation rating of the panel itself.
EN 1794-1 — mechanical performance, for the return as a structure.
Related reading: height versus length, gantry and sign penetrations, and acoustic ratings explained.
Most often because of flanking paths: sound travelling around the ends or through gaps, which the calculation assumed away. Compare measured and calculated results, then look at the ends before adding height.
A perpendicular section at the end of the barrier, turned toward the source side, that intercepts the path around the end. It is usually the cheapest way to improve a barrier that underperforms.
Long enough to break the line of sight from the furthest protected receptor to the source, often several times the barrier height. It should be confirmed by modelling the actual geometry.
Not the whole barrier, but the sector that can see through the gap. That is why a barrier can average well and still fail at one dwelling, and why doors and penetrations need proper detailing.
Usually yes. Terminating against a building, wall or rising ground closes the flank, which a free end in open ground does not. Where the ground falls away, the flank lengthens and performance drops.
Contact Us
Imfornation
Bridge Widening Noise Barrier: Joining a Barrier Across Two DecksShopping Centre Noise: Rooftop Plant and DeliveriesTunnel Approach Noise Barrier: Open Cut, Portal and Cut-and-CoverWind Farm Noise: What a Barrier Can and Cannot DoIndustrial Plant Noise Barrier: Boundary Wall and Equipment EnclosureRail Overbridge Noise Barrier: When the Bridge Is the SourceWastewater Plant Noise: Blowers and Continuous PlantCar Park Noise: Ventilation, Ramps and Rooftop PlantConstruction Site Fencing: Temporary Panels, Welded Mesh or Hoarding3D Curved Fence Panel ManufacturersGabion Retaining Wall: Sizing, Drainage and Stone FillLaboratory Noise: Fume Hoods, Compressors and VibrationTemporary Noise Barrier: Rent or Buy, and What Drives CostGenerator Noise Barrier: Tonal Noise and AirflowIntercity Railway Noise Barrier: Mixed Traffic LinesHighway Noise Barrier Foundation: Piles, Footings and Soft GroundTemporary Fence: Panels, Ballast and Wind Load on SiteAir Source Heat Pump Noise Barrier: Screens and AirflowResidential Noise Barrier: Height, Planning and AppearanceGabion Basket SupplierMetal Noise Barrier ManufacturerFully Enclosed Noise Barrier: Roof, Ventilation and Fire StrategyExpressway Widening: Upgrading an Existing Noise Barrier111Noise Barrier Height or Length: Where the Money Works HarderNoise Barrier Fire Performance: Reaction to Fire and Escape RoutesNoise Barrier End Returns: Why the Last Metres Decide Performance13D-Welded Mesh fencing systemNoise Barrier Structure and Panel Selection: 2 m to 6 mRoad Viaduct Noise Barrier: Deck Edge, Parapet and Load LimitsHospital Noise Barrier: Ward Targets, Height and CleanabilityWarehouse Noise Barrier: Docks, Plant and YardsNoise Control SolutionsMining and Quarry Noise Barriers: Dust, Plant and LayoutQuarry Noise Control: Crushers, Screens and BlastingTraction Substation Noise: Transformer Hum and Cooling PlantAt-Grade Railway Noise Barrier: Level Crossings and Track AccessNoise Barrier Maintenance: Inspection and RepairAirport Noise Barrier: Ground Noise, Run-Up and PlantHighway Interchange Noise Barrier: Multi Level LayoutSolar Noise Barrier Cost: What Drives the Price and the PaybackData Centre Backup Generator Noise: N+1 Testing and Permit LimitsTunnel Portal Noise: Hoods, Barriers and AbsorptionConstruction Hoarding Panels: Wind Load and Site Boundaries