In short: polycarbonate comes as hollow multi-wall sheet, solid sheet and laminated sheet, and the three behave differently on mass, deflection, thermal movement and cleaning. Thickness alone does not decide the acoustic rating; the board type does as much work as the millimetres.
For a comparison of polycarbonate against acrylic and glass, see the transparent materials page. This page is about the board itself: which type, what thickness, how it is held, and where each one belongs.
Hollow multi-wall: two or more walls with ribs between, light and thermally insulating, but low mass.
Solid sheet: a single homogeneous sheet, the heaviest per square metre and the best acoustic performer of the three.
Laminated: two sheets bonded with an acoustic interlayer, used where a rating has to be met at limited thickness.
| Type | Typical thickness | Relative weight | Acoustic behaviour | Where it belongs |
|---|---|---|---|---|
| Hollow twin or multi-wall | 8 to 16 mm | Low | Low mass, rating limited, can drum | Upper bands, low acoustic demand, roof glazing |
| Solid sheet | 10 to 20 mm | High | Best of the three at equal thickness | Roadside and rail barriers where rating governs |
| Laminated | 12 to 25 mm total | Highest | Rating met with damping from the interlayer | High-specification and close-receptor sites |
Because acoustic insulation follows mass, and a hollow sheet is mostly air. The walls are thin, the ribs add stiffness rather than weight, and the panel can resonate between the walls at frequencies that matter for road noise.
It is excellent for daylight and for thermal insulation, which is why it is common in roofing.
It is weak where a DLR figure has to be met at a barrier close to traffic.
Its stiffness is high, so it spans well for its weight, which tempts designers to use it where mass is needed.
Filling the cavities or adding an interlayer changes the behaviour but also the cost and the weight.
Thickness is set by the required rating, the wind load and the deflection limit together. A panel that satisfies the wind load may still fail the rating, and a panel that satisfies the rating may deflect more than the frame allows.
Establish the target DLR first, then find the thickness that reaches it.
Check deflection at the design wind pressure, not only stress.
Allow for thermal expansion, which is significant for polycarbonate.
Confirm the frame can carry the resulting weight, which is several times that of hollow sheet.
Polycarbonate is stiff for its weight, so it spans further than a thin metal cassette of the same mass, and that is exactly why it is over-used. The span has to satisfy two limits at once: the acoustic rating, which depends on mass and does not care about span, and the deflection limit, which depends on thickness and span together.
Reduce the span before increasing the thickness, because thickness drives weight, frame size and cost.
Check the deflection under the design wind pressure with the panel at its service temperature, not at 20 degrees.
Hollow sheet spans well but carries little mass, so a long span and a high rating are not compatible.
Where posts are fixed by the structure behind, the panel module is set by the post spacing, not by the sheet size.
Polycarbonate yellows under ultraviolet unless it has a co-extruded UV layer, and the layer is on one face only. Fitting the panel the wrong way round exposes the unprotected face to the sun, and the panel goes cloudy within a few years.
Mark the UV face at manufacture and check orientation on site.
Do not remove protective film and leave the panel exposed before installation.
Cleaning agents that attack the coating shorten the life dramatically.
Hollow sheet collects dust inside the flutes and cannot be cleaned there.
Allow edge clearance for expansion; trapped panels buckle in summer.
Use compliant gaskets rather than rigid clamps, and avoid direct metal contact.
Keep fixings away from the edge, and predrill rather than drive screws through.
Design for individual replacement, because impact damage is local.
Seal the top edge so water cannot enter the flutes of hollow sheet.
Where daylight or lightness matters more than the last few decibels: an upper band above a solid base, a canopy, a screen where the barrier behind it already does the acoustic work. Used that way it is a sensible product, not a compromise.
Yes, wherever birds are likely to fly at it. The marking is applied at manufacture and cannot be added later, so it has to be decided before the order, and it slightly reduces the transparency that motivated the material in the first place.
Low-pressure water and a mild agent; abrasives scratch permanently.
Clean the lower courses more often, where road spray lands.
Inspect gaskets and edge seals, which fail before the panel does.
Record impact damage so replacements can be batched.
EN 1793-2 — airborne sound insulation rating, DLR.
EN 1794-1 — mechanical performance, including wind load and deflection.
EN 13501-1 — reaction to fire classification.
EN 14388 — product specification for noise reducing devices.
ISO 10847 — in-situ insertion loss, for verification.
Related reading: acrylic versus polycarbonate, panel specifications, and wind load and post spacing.
Only where the acoustic demand is low, such as an upper band above a solid base. Hollow sheet is mostly air, so its mass is low and it can resonate at frequencies that matter for road noise.
Solid is the straightforward choice where thickness is available. Laminated is used where a rating has to be reached within a limited thickness, because the interlayer adds damping at the cost of weight and price.
Set by the target rating, the wind load and the deflection limit together, commonly 10 to 20 mm for roadside work. Deflection rather than strength often governs.
Almost always UV. The protective layer is on one face, and a panel fitted the wrong way round exposes the unprotected side. Cleaning agents that attack the coating have the same effect.
They should be, because impact damage is local. That requires a frame designed for it and a record of panel sizes, so a replacement can be made without remeasuring on site.
Contact Us
Imfornation
Rail Overbridge Noise Barrier: When the Bridge Is the SourceData Centre Cooling Noise: Louvre Screens and Airflow0.85 NRC Noise Barrier WholesaleAnti-Climb Fence Specification: 358 Mesh, Paladin Pales and 3D PanelsNoise Barrier End Returns: Why the Last Metres Decide PerformanceHighway Service Area Noise Barrier: HGV Parking, Plant and Neighbours5m High Noise BarrierNoise Barrier Height: How the Height Is Actually SetNoise Barrier Installation: Sequence, Posts and SealsPermanent or Temporary Noise Barrier: What Actually ChangesShopping Centre Noise: Rooftop Plant and DeliveriesTraction Substation Noise: Transformer Hum and Cooling PlantNoise Control SolutionsRetaining Wall Noise Barrier: Wall Top Mounting and Load PathResidential Noise Barrier: Height, Planning and AppearanceBridge Widening Noise Barrier: Joining a Barrier Across Two DecksAirport Noise Barrier: Ground Noise, Run-Up and PlantSchool Noise Barrier: Cutting Traffic Noise at the ClassroomCooling Tower Noise Barrier: Layout, Airflow and Panel DesignTemporary Noise Barrier: Rent or Buy, and What Drives CostAbsorptive or Reflective Noise Barrier: When Reflection Matters4 Meter Noise Barrier PanelHighway Interchange Noise Barrier: Multi Level LayoutGabion Baskets for sale3D-Welded Mesh fencing systemNoise Barrier Guide: Types, Height, Cost and SelectionExpressway Widening: Upgrading an Existing Noise BarrierBiomass and CHP Noise: Fans, Vents and Continuous DutyConstruction Site Noise Barriers: Temporary Screens That Move With the WorksRailway and HSR Noise Barriers: Design for Speed and ClearanceStadium Noise Barrier: Crowd, PA and Plant CompoundsHospital Noise Barrier: Ward Targets, Height and CleanabilityWind Farm Noise: What a Barrier Can and Cannot DoSign Gantries and Noise Barriers: Passing Structures Through a Barrier LineWarehouse Noise Barrier: Docks, Plant and YardsRailway Station Noise: Platforms, Plant and ApproachesHighway Noise Barrier Cost: What Drives the Price per Square MetrePlace of Worship Noise Barrier: Chimes, PA and Plant358 Security Fence: Mesh, Wire and Anti-Climb SpecificationNoise barriers costLaboratory Noise: Fume Hoods, Compressors and VibrationGabion Mattress: Channel Lining and Scour ProtectionChiller Plant Noise: Barriers, Louvres and AirflowRoad Engineering Noise Barrier: Sections and Structures111