November. 13, 2026
Installing a 358 anti-climb security fence requires more than matching mesh panels with steel posts. Post spacing, panel overlap, fixing arrangements, and foundation capacity must be considered as one structural system. Incorrect coordination can cause alignment problems, uneven panel loading, weak connections, or insufficient support under site-specific conditions.
For high-security projects, these details should be confirmed against the fence layout, approved technical drawings, and actual ground conditions before fabrication and installation.

Post spacing directly affects panel support, connection positioning, and the continuity of the perimeter fence. It should be determined by the selected panel configuration and fixing arrangement rather than calculated by simply using the panel width.
JINBIAO's published 358 fence specifications include several configurations:
| Fence Height | Panel Size (H × W) | Post Section | Post Center Distance |
|---|---|---|---|
| 1800 mm | 1800 × 2518 mm | 60 × 60 × 2 mm | 2530 mm |
| 2000 mm | 2000 × 2518 mm | 60 × 60 × 2 mm | 2530 mm |
| 2400 mm | 2400 × 2518 mm | 60 × 60 × 2 mm | 2530 mm |
| 2400 mm | 2400 × 2518 mm | 60 × 60 × 2 mm | 2440 mm |
| 3000 mm | 3000 × 2218 mm | 80 × 40 × 3 mm | 2440 mm |
| 3300 mm | 3300 × 2218 mm | 80 × 40 × 3 mm | 2440 mm |
The two 2400 mm configurations demonstrate why post spacing should not be assumed from panel dimensions alone. Different connection arrangements may require different post-center distances.
For project planning, the following points need to be checked:
Panel width and the actual distance between adjacent posts.
Panel overlap or connection allowance at each post.
Post section, wall thickness, and required support.
Additional posts at corners, fence ends, and gate openings.
Adjustments where the boundary changes direction or elevation.
The final post layout should be shown on the approved installation drawing to avoid dimensional conflicts during assembly.
The fixing system is a critical part of a 358 security fence. Even when the welded mesh panel meets the specified wire diameter and aperture requirements, an incompatible or insufficiently secured connection can compromise the overall perimeter structure.
JINBIAO's published configurations use flat-bar fixing, with the number of fixing clips varying according to fence height.
A typical flat-bar connection consists of:
Flat Bar: Provides a continuous clamping surface along the panel-to-post interface.
Bolts and Fasteners: Secure the panel and flat bar to the supporting post.
Steel Posts: Provide the structural support for the connected panels.
The fixing quantity should correspond to the selected panel height and approved connection design. JINBIAO's product specifications list 6 fixing clips for 1800 mm panels, 7 for one 2400 mm configuration, 9 for another 2400 mm configuration, and 11–18 for taller configurations.
Three connection details deserve particular attention:
Panel Overlap at Intermediate Posts
Where adjacent panels meet at an intermediate post, the connection must maintain consistent alignment and secure engagement. The overlap or joint arrangement should be confirmed in the fabrication drawing.
Corner Connections
A corner changes the direction of the fence line and introduces a different connection geometry. Corner posts and fixing bars should be selected to accommodate the panel arrangement without forcing panels into an unsuitable position.
Fastener Accessibility and Security
For restricted-access facilities, the fastener arrangement should consider unauthorized removal. Security fasteners can be specified where required by the project, with the exact type confirmed in the technical quotation.
Foundation design should not be separated from post selection. The foundation must provide adequate resistance to the loads transferred through the fence panels and supporting posts.
For a 358 security fence, the foundation design should consider:
| Design Factor | Engineering Consideration |
|---|---|
| Fence Height | Taller panels generally create greater structural demands on the supporting posts and foundations. |
| Post Section | Post dimensions and wall thickness affect the structural capacity of the support system. |
| Wind Load | Local wind conditions and site exposure influence the required foundation design. |
| Soil Conditions | Soil bearing capacity, ground stability, and groundwater conditions affect foundation requirements. |
| Installation Method | Embedded posts and base-plated mounting arrangements require different support details. |
| Ground Elevation | Slopes and changes in ground level can affect post embedment and foundation positioning. |
For embedded-post installations, the foundation dimensions, excavation depth, and concrete specification should be determined by the project design.
For base-plated installations, the base plate, anchor bolts, supporting concrete structure, and edge distances must be checked as a coordinated assembly.
There is no universal foundation size suitable for every 358 fence project. Applying the same foundation dimensions to fences of different heights, soil conditions, and wind exposure can result in inadequate structural support.
Ground conditions can significantly affect the installation of rigid 358 mesh panels.
On sloping sites, two common installation considerations are stepped and raked panel arrangements.
Stepped Installation: Adjacent panels are installed at different elevations to follow the ground profile while maintaining their designed panel geometry.
Raked Installation: Panels are inclined to follow the slope where the ground gradient or project requirements make stepping unsuitable.
The appropriate arrangement depends on the slope, panel dimensions, required ground clearance, and connection design.
Corners, retaining walls, access gates, and transitions between different ground elevations should also be identified before production. These locations may require different post positions or customized panel dimensions.
Accurate site measurements and a complete perimeter layout help reduce unnecessary panel cutting, connection adjustments, and installation delays.
To avoid mismatches between manufactured components and site requirements, contractors should provide the following information when requesting a quotation:
| Required Information | Details to Confirm |
|---|---|
| Fence Layout | Total length, boundary shape, corners, entrances, and site elevations |
| Panel Specifications | Height, width, 76.2 × 12.7 mm mesh opening, and 4 mm wire diameter |
| Post Configuration | Post section, wall thickness, height, and center distance |
| Fixing System | Flat bars, clips, bolts, and required security fasteners |
| Foundation Details | Embedded or base-plated installation and available ground information |
| Surface Treatment | Hot-dip galvanized or galvanized and powder-coated finish |
| Project Requirements | Wind conditions, security requirements, gates, and additional perimeter protection |
Providing these details allows the manufacturer to coordinate panel dimensions, post arrangements, and fixing components before production.
Hebei Jinbiao Construction Materials Tech Corp. manufactures 358 anti-climb security fencing for industrial facilities, airports, correctional facilities, substations, and other high-security perimeter projects.
Our engineering team can work with project drawings and site requirements to coordinate panel configurations, post systems, fixing arrangements, surface treatments, and customized dimensions.
For a project quotation, provide your fence layout, required height, total perimeter length, installation conditions, and technical specifications. Our team can assist in confirming a suitable 358 fence configuration and the corresponding components.
Contact JINBIAO for 358 Anti-Climb Security Fence drawings, technical specifications, and project quotations.