An air source heat pump is a small source with a large nuisance footprint, because it runs for long periods, often through the night, and it is installed within a few metres of a boundary that nobody designed for noise. The complaints that follow are rarely about a loud machine. They are about a steady tonal hum arriving at a bedroom wall.
| Source | Character | What reduces it |
|---|---|---|
| Compressor | Tonal, low frequency, continuous in cold weather | Mass close to the unit; anti-vibration mounting |
| Outdoor fan | Broadband, rising with speed | Airflow-path design; not blocked |
| Defrost cycles | Intermittent, noticeably louder | Timing and setback; a screen helps little |
| Refrigerant pipework | Structure-borne vibration | Isolation and routing, not screening |
Two of these are barrier problems and two are not. A screen that is bought to fix a hum travelling through pipework into a wall will not work, however well it is built.
A heat pump's overall level is modest compared with traffic or plant. The problem is character: a narrow tonal component at the compressor's running frequency, arriving at a quiet facade at night.
Quiet background makes it audible. On a suburban street at 2 a.m. the background is low, so a small tonal source stands out.
Tonality attracts a penalty. Many assessment methods apply a correction for tonal noise, which can turn a compliant level into a non-compliant one.
It runs when it is cold. The coldest nights, when windows are shut and background is lowest, are also when the unit works hardest.
That combination explains why heat pump noise generates so many disputes relative to its measured level.
A screen works on a heat pump in the normal way: it interrupts the path between the unit and the receiver. What makes heat pumps different is how tight the geometry usually is.
Close to the unit is effective — a screen 1 m away does far more than one at the boundary, because the unit is small and the receiver is often just beyond the fence.
Height above the unit matters. A screen that only reaches the top of the casing leaves the fan discharge free to radiate over it.
Line of sight to the neighbour's window governs. If the neighbour is upstairs, a 1.8 m screen at ground level achieves little.
Reflective faces can make it worse. A hard screen close to a wall can bounce sound toward the receiver; an absorptive face avoids that.
An air source heat pump moves a large volume of air, and its efficiency and its defrost behaviour both depend on that flow. Enclosing it fully is not an option; restricting it is a false economy.
Never screen the fan discharge face. Discharge is where most of the air, and much of the noise, leaves.
Keep clearance to the coil face per the manufacturer's installation instructions. Recirculation of cold discharge air reduces output and can cause repeated defrosting.
Use louvred or perforated screens where the screen must sit across an air path, accepting that attenuation drops as open area rises.
Do not box the unit in on all four sides. A three-sided screen open to the least sensitive direction is the usual workable arrangement.
Where the unit is already installed with minimum clearances, there is often no room for an effective screen, and the honest answer is that the fix lies elsewhere: relocation, a quieter unit, anti-vibration mounts, or a change to the operating schedule.
Before specifying anything, three variables decide the outcome, and all three are usually fixed before anyone thinks about acoustics:
| Variable | Effect |
|---|---|
| Distance from unit to boundary | Halving the distance raises the level at the neighbour by roughly 6 dB |
| Height of the receiver | An upstairs window looks over most garden screens |
| Unit selection | Sound power varies substantially between models of the same output |
This is why the most effective heat pump noise measure is usually the one taken at the planning stage: position, orientation and unit selection. A screen is what you use when those decisions have already been made badly.
Anti-vibration mounts under the unit reduce structure-borne transmission into the wall it is fixed to, which a screen cannot address.
Isolate pipework where it enters the building; a rigid pipe is a direct acoustic path.
Fix the screen independently of the building where possible, so it does not re-radiate into the wall.
Allow for service access — a screen that prevents maintenance will be removed and not replaced.
Unit make and model, or its sound power level and airflow.
Position of the unit relative to the boundary and to the nearest window.
Height of the nearest noise-sensitive window above ground.
Which face is discharge, and what clearance the manufacturer requires.
Whether the complaint is a hum, a fan roar, or both.
Any planning or permitted-development condition that applies.
Items three and four decide whether a screen is feasible at all.
Related reading: noise barrier panel range, acoustic louvres for airflow openings, and cooling unit screens and airflow.
It can, if it interrupts the path to the receiver without restricting airflow. Because the unit is usually close to a boundary and the receiver is often a first-floor window, the effective screen has to be positioned and sized for that geometry rather than treated as a garden fence.
Not without designing the airflow. A heat pump needs a large air volume, and boxing it in causes recirculation, reduced output and repeated defrosting. Three-sided screens open away from the sensitive side are the normal compromise.
Partly because the background is quieter, so the same level is more noticeable. Partly because cold weather increases demand and the unit runs harder. And partly because a tonal compressor hum is more intrusive than its level alone suggests.
Only if it is high enough to interrupt the sightline to that window. A ground-level screen protects a ground-floor window well and an upstairs window hardly at all, which is a common source of disappointment after installation.
Anti-vibration mounts, isolating the refrigerant pipework where it enters the building, choosing a quieter unit, relocating it further from the boundary, and scheduling operation. Where clearances are already tight, these often achieve more than a screen that barely fits.
Contact Us
Imfornation
Wind Farm Noise: What a Barrier Can and Cannot DoSchool Noise Barrier: Cutting Traffic Noise at the ClassroomRailway and HSR Noise Barriers: Design for Speed and Clearance111Gabion Retaining Wall: Sizing, Drainage and Stone FillAirport Noise Barrier: Ground Noise, Run-Up and PlantBiomass and CHP Noise: Fans, Vents and Continuous Duty358 Security Fence: Mesh, Wire and Anti-Climb SpecificationHighway Noise Barrier Cost: What Drives the Price per Square MetreSolar Noise Barrier Cost: What Drives the Price and the PaybackNoise barriers costGabion Baskets for sale5m High Noise BarrierConstruction Hoarding Panels: Wind Load and Site Boundaries13D Curved Fence Panel ManufacturersMetal Noise Barrier ManufacturerConstruction Site Fencing: Temporary Panels, Welded Mesh or Hoarding3m High Noise BarrierChain Link Fence: Wire, Mesh and Coating SelectionGabion Basket SupplierNoise Barrier Wind Load: Posts, Spacing and Foundations0.85 NRC Noise Barrier WholesaleResidential Noise Barrier: Height, Planning and AppearanceWarehouse Noise Barrier: Docks, Plant and YardsNoise Barrier Guide: Types, Height, Cost and SelectionPerforated Metal Noise Barrier: Open Area and AbsorptionNoise Control SolutionsData Centre Cooling Noise: Louvre Screens and AirflowMetro Depot Noise Barrier: Enclosure for Depots and Over-Track DevelopmentIndustrial Plant Noise Barrier: Boundary Wall and Equipment EnclosureMining and Quarry Noise Barriers: Dust, Plant and Layout6m High Noise BarrierWastewater Plant Noise: Blowers and Continuous Plant3D-Welded Mesh fencing systemNoise Barrier Maintenance: Inspection and RepairNoise Barrier Panel Specifications: The Six NumbersAnti-Climb Fence Specification: 358 Mesh, Paladin Pales and 3D PanelsNoise Barrier Height: How the Height Is Actually SetTemporary Fence: Panels, Ballast and Wind Load on SiteAir Source Heat Pump Noise Barrier: Screens and AirflowCooling Tower Noise Barrier: Layout, Airflow and Panel DesignDouble Wire Fence: 868 and 656 Panels, Posts and FixingsConstruction Site Noise Barriers: Temporary Screens That Move With the WorksGabion Mattress: Channel Lining and Scour Protection