Airport Fence

High Security Airport Fence Resistant to Forced Entry

What forced entry resistance means on an airport perimeter: cutting time, climbing time, and the gate and ground line where most runs are crossed.
  • High Security Airport Fence Resistant to Forced Entry
  • High Security Airport Fence Resistant to Forced Entry
  • High Security Airport Fence Resistant to Forced Entry
  • High Security Airport Fence Resistant to Forced Entry
High Security Airport Fence Resistant to Forced Entry
Razor topped airport fence along an apron

What Resistance Actually Means

Forced entry resistance is measured in time, not in strength. No perimeter fence stops a determined intruder with the right tools; the question is how long the fence takes to cross and whether that is longer than the response.

Cutting Time

Cutting is the route most intruders take, and mesh resists it by presenting many wires rather than one sheet. A 358 aperture on 4 mm wire means a usable opening needs a series of cuts, each of which is slow and loud.

Wire diameter, not panel size, sets the cutting time. A heavier wire is harder to cut and also harder to bend, which matters on the same attempt.

Panels, posts, topping and gates are quoted against the run and the brief, so the system is agreed before the steel is cut.

Welded mesh perimeter panels with razor coil at dusk

Climbing Time

Concertina razor coil above welded mesh panels

Climbing is defeated by removing the handhold and the foothold. A 76.2 mm by 12.7 mm aperture is too small for a boot; a cranked post carries the topping away from the top wire so the hands have nothing to grip.

Assistance matters as much as the fence. A bin, a wall, a sign post or a tree within reach of the run turns a two-metre fence into a one-metre step.

The Gate and the Ground Line

Gates are the weakest point on almost every site: leaves are shorter than the run, hardware is exposed, and the opening is designed to move.

The ground line is the second. A run set on a wall is stronger than the same run set in soil, because there is no gap to work at the bottom.

Airport perimeter fence run with razor coil on Y posts
Welded mesh fence panels with a coiled topping

Testing Rather Than Claims

A resistance figure that has not been tested is a claim. Where the brief calls for a tested rating, the panel, post and fixing have to be supplied as a tested assembly rather than as separate parts.

For most perimeter work the practical test is simpler: can a person with hand tools and no ladder cross the run before a patrol arrives. That question is answerable from the drawing.

What to Send for a Quotation

Close view of a Y post and razor coil on an airport fence
  • Finished height of the run and of the gates

  • Whether a tested rating is required, and to which standard

  • Panel and wire specification, or the brief if it is not fixed

  • Topping type and whether it is included in the height

  • Ground: soil, concrete or wall

  • Adjacent features within reach of the run

  • Destination port